Probable
Cause
|
Check
|
Remedy
|
| Tool
or spindle binding in external support. |
Disengage
tool and/or loosen bracket containing support. |
Realign
and cycle. |
| Low
hydraulic supply pressure. |
Hydraulic
pressure should be between 300 and 500 psi. |
Regulate. |
| Plunger
valve assembly on retract side of manifold closed. |
Turn
retract cam bar knob to make lever arm depress plunger of plunger
valve assembly. |
If
plunger does not depress, reset cam follower or lever arm on lever
assembly. Ref. Lever Assy. Bul. |
| Retract
feed rate adjustment in manifold is closed. |
Turn
retract feed rate knob counterclockwise to open. |
Adjust. |
| Drive
shaft and spindle coupling bind. |
Remove
spindle assembly and check spline tube for metal build-up. |
File
drive spline and spline tube for free slip movement. Lubricate. |