Probable
Cause
|
Check
|
Remedy
|
| Tool
or spindle binding in external support. |
Disengage
tool and/or loosen bracket containing support. |
Realign
and cycle. |
| Advance
feed rate adjustment at manifold is closed. |
Make
sure feed rate adjustment is open 4 or 5 turns. |
Adjust
- Ref. Eng. Data Bul. |
| Plunger
valve assembly on advance side of manifold closed. |
Turn
advance rapid travel length adjustment counterclockwise (clockwise
for deep hole units) this action should make the lever arm depress
the plunger of the plunger valve assembly. |
If
plunger does not depress, reset cam follower or lever arm on lever
assembly. Ref. Lever Assy. Bul. |