Feed rate slows.
Probable Cause
Check
Remedy
Dirt in compensating feed valve assembly in manifold.
Remove and inspect assembly for dirt.
Clean and replace 22093-2 filters. Ref. Manifold Assembly Bul.
Feed rate adjustments at manifold closed.
Make sure feed rate adjustment is open 4 or 5 turns.
Adjust - Ref. Eng. Data Bul.