Probable
Cause
|
Check
|
Remedy
|
| No
or low hydraulic supply pressure. |
Hydraulic
supply not turned on. |
Correct.
Regulate for proper pressure - 300 to 500 psi. |
| Electrical
and hydraulic connections. |
Correct. |
| Directional
valve at hydraulic pump does not actuate. |
Check "O" rings in valve for swelling or sticking. |
Replace
and lubricate. |
| Hydraulic
supply leaks. |
Check
for leaks around fittings. |
Tighten
or replace. |
| No
electric power to control circuit. |
Make
sure electric system is on. Check fuses. (Solenoid valve action is
audible.) |
Correct. |
| Switches
not being actuated. |
Levers
and cam bars for proper adjustment. |
Readjust
- Ref. Eng. Data Bul., Cam Bar Bul and Lever Assy. Bul. |
| Feed
rate adjustments at manifold closed. |
Make
sure feed rate adjustments are open 4 or 5 turns. |
Adjust
- Ref. Eng. Data Bul. |