Probable
Cause
|
Check
|
Remedy
|
| Air
in hydraulic system. |
Check
for leaks. |
Reseal
leaking area or return to factory for repair. |
| Air
input pressure too low. |
Air
pressure should be above 50 psi. |
Regulate
per Eng. Data. Bul. |
| Thrust
required to advance tool at desired feed rate approaches or exceeds
thrust developed by air cylinder. |
Consult
drilling speed, feed and thrust charts and compare with developed
thrust of unit. |
Decrease
feed rate. Increase input air pressure. Stagger drill lengths. Decrease
size or number of tools. Substitute with hydraulic powered holomatic
unit. |
| Plunger
assembly allows air to enter hydraulic system. |
Remove
and inspect seal and/or plunger. |
Replace