Probable
Cause
|
Check
|
Remedy
|
| Tool
or spindle binding in external support. |
Disengage tool
and/or loosen bracket containing support. |
Realign unit
or external support. |
| Advance
feed rate adjustment at manifold is closed. |
Make
sure feed rate adjustment is open 4 or 5 turns. |
Adjust
- Ref. Eng. Data Bul. |
| Plunger
valve assembly on advance side of manifold closed. |
Turn
advance rapid travel length adjustment counter clockwise, (clockwise
for deep hole units). This action should make lever arm depress plunger
of plunger valve assembly. |
If
plunger does not depress, reset cam follower or lever arm on lever
assembly. Ref. Lever Assy. Bul. |