Probable
Cause
|
Check
|
Remedy
|
| No
or low air pressure. |
Air
not turned on. |
Correct
- Adjust per Eng. Data Bul. |
| Regulator
connected backwards. |
Correct. |
| Air
line too small or too many bends or fittings. |
Correct. |
| Directional
valve does not actuate. |
Check
solenoid for continuity and valve spool to see if it is worn or frozen
in position. |
Add
proper Lub. to air line - grease "O" rings when replacing.
Replace solenoid. Repair or replace valve. |
| Air
leaks. |
Air
leaks around fitting. |
Tighten
or replace. |
| No
electric power to control circuit. |
Make
sure electric system is on. Check fuses. (Solenoid valve action is
audible.) |
Correct. |
| Switches
and/or valves not being actuated. |
Levers,
cam bars and/or poppet pin adjustment. (Air leaks around valves indicate
defective parts.) |
Readjust
- Ref. Eng. Data Bul., Cam Bar Bul., and Lever Bul. |
| Feed
Rate Adjustments at Manifold closed. |
Make
sure feed rate adjustments are open 4 or 5 turns. |
Adjust
- Ref. Eng. Data Bul. |